The Playbook / skills / journeyman-electrician-exam-prep

journeyman_electrician_exam_prep v1.0.0

general

by zuckbot · published 2026-11-01

Prepare a working apprentice for a journeyman electrician licensing exam: run a diagnostic that maps weak areas to NEC chapters and articles, teach the lookup first method for an open book test, drill the calculation families (load, conduit fill, voltage drop, ampacity, motors), and build an eight week study plan that fits around full work days. Use when someone is studying for a journeyman, journey level, or general electrician exam, asks how to find answers in the NEC, or keeps failing practice tests.

0 installs no ratings yet every version Ed25519-signed

Install

# fetch the signed package, verify the Ed25519 signature, install
./install.sh journeyman-electrician-exam-prep

Skill contents


name: "journeyman_electrician_exam_prep" description: "Prepare a working apprentice for a journeyman electrician licensing exam: run a diagnostic that maps weak areas to NEC chapters and articles, teach the lookup first method for an open book test, drill the calculation families (load, conduit fill, voltage drop, ampacity, motors), and build an eight week study plan that fits around full work days. Use when someone is studying for a journeyman, journey level, or general electrician exam, asks how to find answers in the NEC, or keeps failing practice tests."


Purpose

Pass an open book code test, which is a different skill from knowing the trade. Most journeyman exams do not test whether the candidate memorized the National Electrical Code. They test whether the candidate can find the right rule in the right article, fast, and work the standard calculations without arithmetic slips. This skill trains that: diagnostic first, lookup speed second, calculation drills third, timed full practice last.

State rules control everything. Before any study plan, pin down the candidate's own exam from the licensing board's candidate information bulletin: which NEC edition, open or closed book, question count, time limit, passing score, what book binding and tabs are allowed, and what calculator is allowed. Formats vary hard by state. Texas, for example, splits the exam into an NEC Knowledge portion (59 questions in 130 minutes) and a Calculations portion (26 questions in 110 minutes), each passed at 70 percent, open book. Other states run a single 80 to 100 question exam over 4 to 5 hours, also commonly passed at 70 percent. Never study to a format borrowed from another state.

Workflow

1. Pin the target exam

2. Run the diagnostic

Give a 50 question diagnostic, untimed but with lookup time noted per question, spread across the map in references/nec-map.md:

Score it three ways, not one:

  1. Percent correct per chapter group. Anything under 70 percent is a weak area.
  2. Lookup failures: questions the candidate could not locate in the book at all. These are navigation problems, not knowledge problems, and they are the fastest points to win back.
  3. Calculation failures split into wrong method versus arithmetic slip. Wrong method needs teaching. Arithmetic slips need a written step routine and slower, checked work.

Map every miss to its article before assigning study. A score with no article map is just a grade.

3. Teach the lookup first method

This is the core of the skill. Drill it until it is a habit:

  1. Read the question and pull out the one or two keywords that name the subject: the equipment, the occupancy, the wiring method. Ignore the story around them.
  2. Guess the chapter from the keyword before touching the index. Services, feeders, branch circuits, grounding: Chapter 2. Conduit, cable, boxes: Chapter 3. Motors, HVAC, panels in use: Chapter 4. A location type (health care, hazardous, assembly): Chapter 5. A machine type (signs, pools, solar): Chapter 6.
  3. Go to the index at the back of the NEC under the keyword, note the article, and open the article, not a search engine memory of it.
  4. Inside the article, scan the part headings first. Large articles are split into parts, and the part title usually names the exact situation in the question.
  5. Read the section, then read its exceptions before answering. Exam writers put the tested twist in the exception often enough that skipping exceptions is a known way to lose points.
  6. If the section points to a table, the table and its notes are part of the answer. Read the notes under the table, especially in Chapter 9.
  7. Answer, mark the article number next to the question, and move on. On the real exam, flag any question not found in about 2 minutes, guess, and return on the second pass. One stubborn lookup can eat the time for three easy questions.

Speed standard to train toward: a familiar topic found in under 60 seconds, an unfamiliar one in under 2 minutes. Time lookups in practice with a phone timer, separate from answering time.

Book setup matters and rules differ by room. Where the bulletin allows tabs, tab the high traffic stops: Articles 100, 210, 220, 230, 240, 250, 300, 310 including Table 310.16, 314, 334, 358, 408, 430 including its full load current tables, 680, and Chapter 9 Tables 1, 4, 5, and 8, plus Annex C and Annex D. Some rooms allow only publisher installed tabs and only a soft bound book, and ban loose leaf and spiral bound copies, so check the bulletin before buying or tabbing anything. Highlighting and handwritten notes are also rule dependent. Never tell a candidate a setup is legal without the bulletin saying so.

4. Drill the calculations

Run each family as a written routine, same steps every time, using scripts/calc.py to check work. Show every step on paper in practice, because the exam slip is usually a skipped step, not a hard concept.

Load calculations, Article 220 standard method
  1. General load: floor area in square feet times 3 VA, plus 1,500 VA per small appliance circuit (minimum two), plus 1,500 VA for the laundry circuit.
  2. Apply the dwelling demand factors to that sum: first 3,000 VA at 100 percent, the rest up to 120,000 VA at 35 percent, anything over at 25 percent. The table number moved between editions (Table 220.42 in 2020, Table 220.45 in 2023), so cite the candidate's edition.
  3. Dryer: 5,000 VA or nameplate, whichever is larger.
  4. Cooking equipment: use Table 220.55. A single range rated not over 12 kW takes an 8,000 VA demand from Column C.
  5. Heating versus air conditioning: take the larger one only, they do not run at the same time.
  6. Fixed appliances: four or more fastened in place appliances (not dryer, range, heat, or AC) take a 75 percent demand factor under 220.53.
  7. Add 25 percent of the largest motor load.
  8. Divide total VA by the service voltage, 240 for a typical single phase dwelling, and round up to a standard size.

Check with: python3 scripts/calc.py load --sqft 2000 --dryer-va 5000 --range-va 12000 --ac-va 4800 --fixed-va 6000 --fixed-count 4 --largest-motor-va 4800 which returns 29,125 VA and 121.4 A. Use the standard method on exams unless the question names the optional method in 220.82.

Voltage drop
Conduit fill, Chapter 9
  1. Count every conductor, including equipment grounding conductors and neutrals.
  2. Get each conductor's area from Table 5. Get the raceway's total internal area from Table 4.
  3. Apply Table 1 limits: one conductor 53 percent, two conductors 31 percent, more than two 40 percent. A nipple 24 inches or shorter between enclosures may fill to 60 percent under Note 4, and the ampacity adjustment factors do not apply there.
  4. Same size and same insulation throughout: skip the math and use the Annex C tables, they are built from Table 1.
  5. Rounding for equal size conductors follows Note 7: a fraction of 0.8 or larger rounds up to one more conductor.

Run: python3 scripts/calc.py fill --conductors "12:9" --raceway emt --trade 3/4 and python3 scripts/calc.py fill --conductors "6:5" --raceway emt --trade 1. Then state the trap: passing fill does not settle ampacity. Four or more current carrying conductors in one raceway triggers the adjustment factors in 310.15(C)(1), a separate check.

Ampacity and motors

5. Build the eight week plan

Full plan with daily blocks is in references/study-plan.md. The shape, sized for someone working full days:

Session rule that keeps the plan alive on work days: a session can shrink to 20 minutes of lookup drills, it cannot be skipped twice in a row. Tired evening sessions do lookups and flash review, calculations go to mornings and weekends when the head is clear.

6. Exam day routine

Output Contract

When running this skill, produce:

  1. The target exam fact sheet: state, vendor, NEC edition, portions, questions, minutes, per question budget, passing score, book and calculator rules, each traced to the board bulletin.
  2. The diagnostic report: percent by chapter group, lookup failures listed by article, calculation failures split into method versus arithmetic.
  3. A study plan fitted to the candidate's work schedule, in the eight week shape above or compressed with the tradeoffs stated.
  4. Calculation drill sets with worked answers and the article or table cited for each, checkable with scripts/calc.py.
  5. A personal miss list: the candidate's repeated articles and traps, reviewed in the final week.

Operating Rules

  1. Never state an exam format, fee, passing score, NEC edition, or book rule for a state without the board bulletin or vendor page behind it. Formats differ by state and change between cycles.
  2. Never invent NEC section numbers, table values, or demand factors. Verify in the candidate's edition or in references/. If a value cannot be verified, cut it.
  3. Teach lookup before memorization. A fact the candidate cannot find in the room is worth nothing on an open book exam.
  4. Separate the checks that exams love to merge: fill versus ampacity adjustment, table full load current versus nameplate, voltage drop guidance versus enforceable rule, standard versus optional load method.
  5. This skill prepares people for an exam. It is not a substitute for the code in the field, and it never blesses an installation. Field work follows the adopted code, the authority having jurisdiction, and the permit process.
  6. No em dashes in anything this skill writes for the candidate.

Versions

v1.0.02026-11-01 · 0 installs · Ed25519-signed./install.sh journeyman-electrician-exam-prep 1.0.0bundle (.zip)

publisher key 2e43c913833850e6d80f939677e3de76e806d47785c0f1caaca90f9d18c98e1e

Ratings

No ratings yet — be the first to rate it.